3com 3CNJPSE24 Manual do Utilizador Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 22
Appendix A — Safety Information
Ethernet Power Supply User s Guide A-3
§ Installation and removal of the Ethernet Power Supply must
be carried out by qualified personnel only.
§ Power Cord Set:
The power cord must be approved for the country in which
it is used:
U.S.A. and
Canada
§ The cord set must be UL-
approved and CSA certified.
§ The minimum specification for
the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
§ The cord set must have a rated
current capacity of at least 10A.
§ The attachment plug must be
an earth-grounding type with a
NEMA 5-15P (15A, 125V) or
NEMA 6-15P (15A, 250V)
configuration.
Denmark § The supply plug must comply
with section 107-2-D1, standard
DK2-1a or DK2-5a.
Switzerland § The supply plug must comply
with SEV/ASE 1011.
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 39 40

Comentários a estes Manuais

Sem comentários