U
NTERMINATED
E
THERNET
10BASE-2 (BNC)
M
ODULE
I
NSTALLATION
G
UIDE
For the LANplex 2500/2016
Module Description
This module contains eight (8) unterminated Ethernet 10BASE-2 ports that
use BNC connectors. I
f a port on this module is at the end of a 10BASE-2
(BNC) segment, you must provide an external 50 Ohm terminator.
When the port is at the end of a segment, using a T connector with a
terminating plug may cause interference with adjacent ports. 3Com
recommends terminating ports with the ITT Pomona Y connector, Model
4896, with a terminating plug on the end, or the ITT Pomona Feed-Thru
Terminator, Model 4119-50. When the port is in the middle of a segment, the
Y connector may be necessary.
Prior to installing the unterminated 10BASE-2 (BNC) module, LANplex
system software revision 7.0.0 or later and LANplex diagnostics software
revision 3.0.2 or later must be installed. A system software revision
supporting this module is available from the 3com BBS, the Internet FTP site
(3Com.ftp.com), or 3Com Forum on Compuserve, or 3Coms Web site
(http://infodeli.3com.com/infodeli/swlib/switch_files.htm).
For a description of how to configure this module into your network, see
the LANplex documentation set.
Audience
This guide is intended for trained technical personnel only.
Port Status
Unterminated
12345
6
7
8
Active
Error
Board
Error
R
Vista de página 0
1 2 3 4 5 6

Resumo do Conteúdo

Página 1

U NTERMINATED E THERNET 10BASE-2 (BNC)M ODULE I NSTALLATION G UIDE For the LANplex 2500/2016 Module Description This module contains eight (8) un

Página 2 - Read if initial

Status LEDs The option module contains one Board Error LED, eight port status Active LEDs, and eight port status Error LEDs. Depending on the

Página 3 - Read if replacing

To remove the faceplate: 1 Loosen the two captive screws securing the faceplate to the chassis. 2 Pull the faceplate away from the system. Read if

Página 4 - WARNING:

The LANplex system will automatically reset when a module has been installed with the power on. If you physically change the configuration of the syst

Página 5

4 To seat the module, firmly push the module forward to engage the module and backplane connectors. You will feel a slight resistance as the connector

Página 6 - 95052-8145

3Com Corporation 5400 Bayfront PlazaSanta Clara, California95052-8145 © 3Com Corporation, 1996. All rights reserved. No part of this documentation ma